Skip to content
Operations
Skill

/unifi-access

How to manage UniFi Access door control — locks, credentials, visitors, access policies, and events. Use this skill when the user mentions UniFi Access, door locks, door access, building access, NFC cards, PIN codes, visitor passes, access policies, access schedules, door

BOOST
From plugin
unifi-mcp
90516 skills
Install
$ npx -y skills add sirkirby/unifi-mcp --skill unifi-access --agent claude-code

How it fires

How this skill gets triggered: by you, by Claude, or both.

  • Fires itselfAuto-invocation. Claude auto-loads it when your prompt matches the work.Auto-invocation is when the right skill fires by itself at the right moment, driven by a FLOW.md router and a hook, instead of you invoking it by name. It is the difference between a skill being installed and a skill actually getting used.Read the full definition →
  • You can call itInvoke it directly when you want it.
  • Slash command/unifi-access

Context preview

The summary Claude sees to decide when to auto-load this skill.

How to manage UniFi Access door control — locks, credentials, visitors, access policies, and events. Use this skill when the user mentions UniFi Access, door locks, door access, building access, NFC cards, PIN codes, visitor passes, access policies, access schedules, door

SKILL.md

unifi-access.SKILL.md
name: unifi-access
description: How to manage UniFi Access door control — locks, credentials, visitors, access policies, and events. Use this skill when the user mentions UniFi Access, door locks, door access, building access, NFC cards, PIN codes, visitor passes, access policies, access schedules, door readers, or any UniFi Access task.

UniFi Access MCP Server

Dependencies

Requires: access Optional: network

Verify required tools through MCP discovery before collecting data; discovery alone does not prove controller connectivity or authorization. If a required server/tool is missing or a required read fails, stop and report it unavailable. Optional sources may be skipped only when the report visibly names the missing source and resulting coverage limits. Use the product setup skill for connection help; never request secrets.

Coverage and Limitations

Every report must include a **Coverage and Limitations** section: name each requested source and its status (available, unavailable, partial, or capped), requested time window/timezone or current-state collection time, actual filters, returned counts, limits, pagination, and any failed calls or unknown fields. Counts describe retrieved records, not totals unless completeness is established. A successful empty query is an observation; a failed or missing source is unavailable, never an empty result. If a limit is reached, label the source capped unless further bounded reads establish coverage. If completeness cannot be established, label it partial. Do not claim complete coverage, all-clear, or overall health from unavailable, partial, or capped data; say “No concerning activity found in the retrieved records” when appropriate.

Separate **Observations** (cite source/tool, record ID and timestamp when available), **Hypotheses** (correlations and alternative explanations), and **Identity** (only explicit source-backed credential/account attribution, with its limits). Timing, similar names, proximity, or absence of a matching event alone proves neither identity nor cause. A credential event identifies the recorded account, not who physically used it. Missing mappings or clock uncertainty limit correlations.

You have access to a UniFi Access MCP server that lets you query and manage a UniFi Access controller. It provides 37 tools covering doors, locks, credentials, visitors, access policies, events, devices, and system health.

Tool Discovery

The server uses **lazy loading** by default — only meta-tools are registered initially:

| Meta-Tool | Purpose | |-----------|---------| | `access_tool_index` | Discover tools by name/description; use `category`, `search`, or `include_schemas` to filter | | `access_execute` | Call any tool by name (essential in lazy mode) | | `access_batch` | Run multiple tools in parallel | | `access_batch_status` | Check async batch job status |

**Workflow:** Call `access_tool_index` to find the right tool, then `access_execute` to call it. Use `access_batch` for multiple independent queries.

Safety Model

**All mutations are disabled by default** because Access controls physical door locks and building entry.

**Read operations** — always available. Listing doors, events, users, credentials — all work without permissions.

**Mutations** require explicit opt-in via env vars:

  • `UNIFI_POLICY_ACCESS_DOORS_UPDATE=true` — lock/unlock doors
  • `UNIFI_POLICY_ACCESS_CREDENTIALS_CREATE=true` — create NFC/PIN/mobile credentials
  • `UNIFI_POLICY_ACCESS_CREDENTIALS_DELETE=true` — revoke credentials
  • `UNIFI_POLICY_ACCESS_VISITORS_CREATE=true` — create visitor passes
  • `UNIFI_POLICY_ACCESS_VISITORS_DELETE=true` — delete visitor passes
  • `UNIFI_POLICY_ACCESS_POLICIES_UPDATE=true` — update access policies
  • `UNIFI_POLICY_ACCESS_DEVICES_UPDATE=true` — reboot devices

**Confirmation flow** — every mutation uses preview-then-confirm: 1. Default call → returns preview of what would change 2. Call with `confirm=true` → executes the mutation

Door lock/unlock operations are **physical real-world actions** — always preview first.

Response Format

All tools return: `{"success": true, "data": ...}`, `{"success": false, "error": "..."}`, or `{"success": true, "requires_confirmation": true, "preview": ...}`. Always check `success` first.

**Redacted secrets:** Credential `token` and `pin_code` values come back as `***REDACTED***` by default in reads, lists, and create previews. Raw values are controlled by process policy (`UNIFI_ACCESS_REDACT_SENSITIVE_FIELDS=false` or global `UNIFI_REDACT_SENSITIVE_FIELDS=false`), not by tool arguments. Never echo `***REDACTED***` back into a create/update — it is rejected so the placeholder can't be stored as a real credential.

Key Capabilities

  • **Door control:** `access_lock_door` / `access_unlock_door` — unlock relocks automatically after duration (default 2 seconds)
  • **Real-time events:** `access_recent_events` reads from websocket buffer instantly. Event types: `door_open`, `door_close`, `access_granted`, `access_denied`, `door_alarm`
  • **Historical events:** `access_list_events` with time/door/user filters. Topics: `admin` or `admin_activity`
  • **Activity summary:** `access_get_activity_summary` aggregates events over a time period — useful for security audits
  • **Credentials:** Create NFC (`{user_id, token}`), PIN (`{user_id, pin_code}`), or mobile (`{user_id}`) credentials
  • **Visitor passes:** Developer API family with scoped UUIDs, ISO 8601 `valid_from`/`valid_until`, and optional contact/company metadata

Dual Authentication

Access has two independent auth paths:

  • **API key (port 12445)** — official Developer API operations, including visitor list/get/create/delete
  • **Username + password (port 443)** — proxy-backed operations such as credentials and policies

Either can work independently for its supported tools. For full functionality, configure both. Visitor auth failures require checking `UNIFI_ACCESS_API_KEY`; proxy-backed mutation failures require ch

Read more
Ships withunifi-mcp

Leverage agents and agentic AI workflows to manage your UniFi deployment.

Get the whole plugin

Other skills on unifi-mcp.