Skip to content
Automation
Skill

/tia-networks

C# Openness implementation of topology and low-level network engineering.

From plugin
totally-integrated-claude
8718 skills1 MCP

Claude Code

$ npx -y skills add Czarnak/totally-integrated-claude --skill tia-networks --agent claude-code

SKILL.md

tia-networks.SKILL.md
name: tia-networks
description: >
  C# Openness implementation of topology and low-level network engineering.
license: MIT

tia-networks

Scope

Topology and low-level network engineering — full C# Openness implementation.

When the roadmap routes here, the entire solution is C#. Do not mix with Python wrapper calls. Always load `tia-csharp-common` first (done by roadmap).

---

Reference files

Load ONLY the reference file(s) relevant to the task. Do not load all files at once.

| Reference file | Load when the task involves | |---|---| | `references/subnets-and-nodes.md` | Reading/writing subnet attributes (name, type, PROFIBUS bus params, isochronous settings); accessing node attributes (IP address, PROFINET device name, node type); SubnetOwner service | | `references/io-systems.md` | PROFINET IO system attributes; DP master system (IoSystem) attributes; TransferArea creation/deletion on PN or DP interfaces | | `references/addresses-and-channels.md` | Address objects (StartAddress, IoType, Length, IsochronousMode, ProcessImage); channel access (ChannelType, ChannelIoType); AddressController service | | `references/io-timing.md` | IoConnector timing/watchdog attributes (PnUpdateTime, PnWatchdogFactor, RtClass, SyncRole); IO device interface isochronous settings (PnSendClock, IsochronousTi, IsochronousTo) | | `references/communication-connections.md` | Configuring and inspecting S7, FDL, ISO, ISO-on-TCP, TCP, UDP, PTP, and HMI communication connections through `CommunicationManagement.Connections` | | `references/online-connection-configuration.md` | Choosing/inspecting online connection paths with `ConnectionConfiguration`: modes, PC interfaces, target interfaces, subnets, gateways, accessible devices, and `ApplyConfiguration` |

For tasks spanning multiple areas, load all relevant reference files before generating code.

---

Safety and dependency gate

  • Resolve project, device, recursive device-item path, interface/node, subnet, IO system,

and connection with exact selectors. A name alone is insufficient when the same name can occur in another group or interface.

  • Obtain explicit authorization for the exact topology, address, timing, connection, or

online-path mutation. Read-only discovery and static validation are not authorization.

  • Before delete, disconnect, reconnect, readdress, or subnet replacement, inventory every

dependent node, IO system, communication connection, assigned PLC tag/address, and online route that the change can affect.

  • Bind that dependency inventory to the proposed change. If any connection endpoint or

selector cannot be identified completely, return `dependency_evidence_incomplete` and refuse the mutation.

  • Use `ExclusiveAccess` and a transaction where the operation supports them, then compile

the affected hardware/software. Do not save after ambiguous selection, partial mutation, incomplete dependency evidence, or compile/consistency failure.

  • Applying an online connection configuration, enumerating accessible devices, or going

online is a live operation. Keep it separate from offline topology edits and require the exact target and PC interface to be authorized.

---

Execution pattern

1. Access devices and device items from `Project.Devices` 2. Navigate network interfaces and nodes via Openness HW namespace 3. Use `GetService<SubnetOwner>()` to access subnets owned by a device item 4. Use `GetService<NetworkInterface>()` to access the network interface 5. Resolve exact endpoints and complete dependency evidence before creating or modifying IO systems, subnets, nodes, or connections 6. Modify addresses or channel timing via `deviceItem.Addresses` / `deviceItem.Channels` 7. Use `GetService<CommunicationManagement>()` for configured communication connections 8. Use `OnlineProvider.Configuration` only for online connection-path selection, not for project topology creation 9. Compile hardware after changes, inspect the complete result, and save only on success (see `tia-project-general/references/compile.md`)

Read more
@czarnak
Ships withtotally-integrated-claude

An agent plugin for Siemens TIA Portal engineering automation, compatible with Claude Code, Codex, and GitHub Copilot in VS Code and Copilot CLI.

8718 skills1 MCP
Get the whole plugin

Stars on GitHub

Momentum

stars in total
87
Star history of Czarnak/totally-integrated-claude on GitHub, a chart by star-history.com

Other skills on totally-integrated-claude.

More skills from other plugins.

agent-builder

agent-builder

Load immediately after an Agent intent, before the first agent_builder_* call. Governs how you create, configure, test, and…

n8n2w209k
@n8n-io@n8n-ioInstall Skill
browser-use

browser-use

Direct browser control via CDP for web interaction: automation, scraping, testing, screenshots, and site/app work. Also covers…

@browser-use@browser-useInstall Skill
agent-browser

agent-browser

Browser automation CLI for AI agents. Use when the user needs to interact with websites, including navigating pages, filling…

@vercel-labs-2@vercel-labs-2Install Skill
add-anydoc

add-anydoc

Add local office-document-to-Markdown conversion to NanoClaw agent containers with the pinned Firecrawl AnyDoc CLI. Use when…

@nanocoai@nanocoaiInstall Skill

Questions about tia-networks.

Which coding agents can use tia-networks?
tia-networks installs in Claude Code, Codex, Cursor, Gemini CLI, GitHub Copilot, OpenCode and Windsurf with the skills CLI, using each agent's flag shown on this page. Flowy's auto-invocation, which fires a skill when your prompt matches, runs in Claude Code only.