alphafold
Validate protein designs using AlphaFold2 structure prediction. Use this skill when: (1) Validating designed sequences fold…
Guidance for SPR and BLI binding characterization experiments. Use when: (1) Planning binding kinetics experiments, (2) Troubleshooting poor/no binding signal, (3) Interpreting kinetic data artifacts, (4) Choosing between SPR vs BLI platforms.
$ npx -y skills add adaptyvbio/protein-design-skills --skill binding-characterization --agent claude-codeHow it fires
How this skill gets triggered: by you, by Claude, or both.
/binding-characterizationContext preview
The summary Claude sees to decide when to auto-load this skill.
Guidance for SPR and BLI binding characterization experiments. Use when: (1) Planning binding kinetics experiments, (2) Troubleshooting poor/no binding signal, (3) Interpreting kinetic data artifacts, (4) Choosing between SPR vs BLI platforms.
name: binding-characterization description: > Guidance for SPR and BLI binding characterization experiments. Use when: (1) Planning binding kinetics experiments, (2) Troubleshooting poor/no binding signal, (3) Interpreting kinetic data artifacts, (4) Choosing between SPR vs BLI platforms. license: MIT category: experimental tags: [binding, spr, bli, validation]
| Factor | Choose SPR | Choose BLI | |--------|------------|------------| | **Sensitivity** | Small molecules, fragments (<500 Da) | Large complexes, antibodies | | **Throughput** | Low-medium (serial) | High (96-well parallel) | | **Sample purity** | Required (clogs fluidics) | Tolerates crude lysates | | **Kinetic resolution** | Higher (better for fast kinetics) | Lower | | **Mass transport** | More sensitive (may distort kon) | Less sensitive | | **Maintenance** | High (fluidics system) | Low (dip-and-read) | | **Sample consumption** | Higher (continuous flow) | Lower | | **Cost per experiment** | Lower chip cost, higher run cost | Higher tip cost, lower run cost |
---
| Cause | Mechanism | Solution | |-------|-----------|----------| | **Hydrophobic CDRs** | Adsorb to SPR gold/dextran surface | Add 0.05% Tween-20, use CM7 chip with longer dextran | | **Aggregation** | Mass transport artifacts in SPR fluidics | Filter sample (0.22μm), reduce ligand density | | **High instability** | Degrades during continuous flow | Shorter cycle time, add stabilizers (trehalose 5%) | | **Charge mismatch** | Nonspecific binding to charged dextran | Adjust buffer pH ±1 from pI, add BSA 1mg/mL | | **Slow dissociation** | Long regeneration needed (damages ligand) | Use BLI (disposable tips) |
| Cause | Mechanism | Solution | |-------|-----------|----------| | **Small analyte** | BLI less sensitive for <10 kDa | Use SPR with appropriate chip | | **Weak affinity (KD >10μM)** | Fast dissociation in BLI dip | Increase analyte concentration | | **Low expression** | Not enough signal | Increase biosensor loading |
---
Mass transport limitation occurs when analyte cannot diffuse to the surface fast enough to maintain equilibrium. This distorts kinetic parameters.
| Strategy | SPR | BLI | |----------|-----|-----| | Reduce ligand density | <200 RU for high-affinity | <0.5 nm shift loading | | Increase flow rate | 50-100 μL/min | Increase shake speed (1000 rpm) | | Use oriented immobilization | His-tag capture | Biotinylated ligand | | Include in fitting | Mass transport model (kt) | Usually less critical |
---
| Additive | Concentration | Mechanism | Best For | |----------|---------------|-----------|----------| | BSA | 0.5-1 mg/mL | Blocks hydrophobic sites | General use | | Tween-20 | 0.02-0.05% | Prevents surface adsorption | Hydrophobic analytes | | Trehalose | 1-5% | Stabilizes + blocks | Unstable proteins | | Sucrose | 5% | BLI-specific blocker | BLI tips | | Carboxymethyl dextran | 1 mg/mL | Competitive blocking | SPR with charged proteins | | NaCl | 150-500 mM | Reduces ionic interactions | Charged proteins |
**Always include**:
---
| Condition | Targets | Caution | |-----------|---------|---------| | 10 mM Glycine pH 2.0-2.5 | Most protein-protein | May denature ligand | | 10 mM Glycine pH 1.5 | Strong interactions | Harsh, limit exposure | | 1-2 M NaCl | Ionic interactions | Mild, try first | | 10 mM NaOH | Very stable ligands | Can hydrolyze proteins | | 10 mM Glycine pH 9-10 | Acid-stable proteins | Can aggregate | | 10 mM EDTA | His-tag, metal-dependent | Strips Ni-NTA | | 4 M MgCl2 | Hydrophobic interactions | Check ligand stability |
1. Start with mildest condition (high salt) 2. Test 30s contact time 3. Verify complete dissociation (return to baseline) 4. Verify retained ligand activity (repeat binding) 5. Use shortest effective contact time
---
**Symptoms**: Two-rate association or dissociation **Causes**:
**Solutions**:
Validate protein designs using AlphaFold2 structure prediction. Use this skill when: (1) Validating designed sequences fold…
End-to-end binder design using BindCraft hallucination. Use this skill when: (1) Designing protein binders with built-in AF2…
Guidance for choosing the right protein binder design tool. Use this skill when: (1) Deciding between BoltzGen, BindCraft, or…
Structure prediction using Boltz-1/Boltz-2, an open biomolecular structure predictor. Use this skill when: (1) Predicting protein…
All-atom protein design using BoltzGen diffusion model. Use this skill when: (1) Need side-chain aware design from the start, (2)…
Goal-oriented binder design campaign planning and health assessment. Use this skill when: (1) Planning a complete binder design…