/dicom-series-to-volume
Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
$ npx -y skills add NVIDIA/skills --skill dicom-series-to-volume --agent claude-codeHow it fires
How this skill gets triggered: by you, by Claude, or both.
- Fires itselfAuto-invocation. Claude auto-loads it when your prompt matches the work.Auto-invocation is when the right skill fires by itself at the right moment, driven by a FLOW.md router and a hook, instead of you invoking it by name. It is the difference between a skill being installed and a skill actually getting used.Read the full definition →
- You can call itInvoke it directly when you want it.
- Slash command
/dicom-series-to-volume
Context preview
The summary Claude sees to decide when to auto-load this skill.
Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
SKILL.md
dicom-series-to-volume.SKILL.mdname: dicom-series-to-volume
description: Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
license: Apache-2.0
allowed-tools: Bash
metadata:
author: NVIDIA MedTech Team
tags:
- MedTech
- DICOM
- NIfTIdicom_series_to_volume
Purpose
- Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
- Use the wrapper exactly as documented; do not replace the upstream entrypoint with a handwritten implementation.
- Manifest I/O: inputs are `dicom_dir`; outputs are `nifti_volume` and `result_json`.
Instructions
- Read `skill_manifest.yaml` before changing arguments, side effects, or validation gates.
- Run `scripts/series_to_volume.py` through the documented command below; keep outputs under a caller-provided run directory.
- If a host agent exposes `run_script`, use `run_script("scripts/series_to_volume.py", args=[...])`; otherwise run the Bash/Python command shown below.
- Check the emitted JSON and the paired `dicom_volume_quality_v1` verifier before treating the run as evidence.
Available Scripts
| Script | Purpose | Arguments | |---|---|---| | `scripts/series_to_volume.py` | Primary entrypoint declared by skill_manifest.yaml. | `PATH_TO_DICOM_DIR [--output OUT.nii.gz]` |
Prerequisites
- Runtime requirements: Python packages listed in `runtime.side_effects.pip_packages`.
- Run commands from the repository root unless an existing section below says otherwise.
Limitations
- Single-series only; multi-series input is rejected at preflight.
- Multi-frame DICOM (NumberOfFrames > 1 per file) not supported.
- Compressed transfer syntaxes (JPEG / JPEG2000 / RLE) not supported.
- No voxel reorientation. The affine is derived from DICOM headers and represented in NIfTI/RAS coordinates; a downstream gate (e.g. expected_axcodes) is expected to assert orientation before this volume is fed to a segmentation model.
- Not for clinical deployment, autonomous diagnosis, regulatory submission, production inference (use a vetted converter such as dcm2niix for that).
Troubleshooting
| Error | Cause | Fix | |---|---|---| | Missing dependency or import error | Runtime package drift from `skill_manifest.yaml`. | Install the packages declared in the manifest or use the documented setup command. | | Empty or schema-invalid output | Wrong input path, unsupported modality, or upstream failure. | Re-run with a known fixture and inspect the wrapper JSON plus stderr. | | Validation gate failure | Output violated a declared engineering invariant. | Keep the failed evidence pack and use the gate message to repair inputs or wrapper code. |
Reads one DICOM series, sorts slices by `ImagePositionPatient`, applies `RescaleSlope` and `RescaleIntercept`, builds an affine from orientation and spacing tags, and writes a `.nii.gz` plus JSON summary.
python scripts/series_to_volume.py PATH_TO_DICOM_DIR --output PATH_TO_OUT.nii.gz
For a trusted run with the paired verifier:
python -m eval_engine.run_trusted skills/dicom-series-to-volume \
--fixture PATH_TO_DICOM_DIR \
--out runs/dicom_series_to_volume_trusted
Key output fields: `n_slices`, `series_instance_uid`, `output.path`, `output.shape`, `output.spacing`, `output.axcodes`, `output.affine`, `hu_range`, and `runtime.conversion_seconds`.
Scope limits: single-series CT only; no multi-frame DICOM, compressed transfer syntax handling, RT structure sets, auto-reorientation, or clinical use.
Read more
name: dicom-series-to-volume
description: Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
license: Apache-2.0
allowed-tools: Bash
metadata:
author: NVIDIA MedTech Team
tags:
- MedTech
- DICOM
- NIfTIdicom_series_to_volume
Purpose
- Used for converting one CT DICOM series folder to a HU NIfTI volume with affine evidence. Not for multi-frame DICOM or clinical use.
- Use the wrapper exactly as documented; do not replace the upstream entrypoint with a handwritten implementation.
- Manifest I/O: inputs are `dicom_dir`; outputs are `nifti_volume` and `result_json`.
Instructions
- Read `skill_manifest.yaml` before changing arguments, side effects, or validation gates.
- Run `scripts/series_to_volume.py` through the documented command below; keep outputs under a caller-provided run directory.
- If a host agent exposes `run_script`, use `run_script("scripts/series_to_volume.py", args=[...])`; otherwise run the Bash/Python command shown below.
- Check the emitted JSON and the paired `dicom_volume_quality_v1` verifier before treating the run as evidence.
Available Scripts
| Script | Purpose | Arguments | |---|---|---| | `scripts/series_to_volume.py` | Primary entrypoint declared by skill_manifest.yaml. | `PATH_TO_DICOM_DIR [--output OUT.nii.gz]` |
Prerequisites
- Runtime requirements: Python packages listed in `runtime.side_effects.pip_packages`.
- Run commands from the repository root unless an existing section below says otherwise.
Limitations
- Single-series only; multi-series input is rejected at preflight.
- Multi-frame DICOM (NumberOfFrames > 1 per file) not supported.
- Compressed transfer syntaxes (JPEG / JPEG2000 / RLE) not supported.
- No voxel reorientation. The affine is derived from DICOM headers and represented in NIfTI/RAS coordinates; a downstream gate (e.g. expected_axcodes) is expected to assert orientation before this volume is fed to a segmentation model.
- Not for clinical deployment, autonomous diagnosis, regulatory submission, production inference (use a vetted converter such as dcm2niix for that).
Troubleshooting
| Error | Cause | Fix | |---|---|---| | Missing dependency or import error | Runtime package drift from `skill_manifest.yaml`. | Install the packages declared in the manifest or use the documented setup command. | | Empty or schema-invalid output | Wrong input path, unsupported modality, or upstream failure. | Re-run with a known fixture and inspect the wrapper JSON plus stderr. | | Validation gate failure | Output violated a declared engineering invariant. | Keep the failed evidence pack and use the gate message to repair inputs or wrapper code. |
Reads one DICOM series, sorts slices by `ImagePositionPatient`, applies `RescaleSlope` and `RescaleIntercept`, builds an affine from orientation and spacing tags, and writes a `.nii.gz` plus JSON summary.
python scripts/series_to_volume.py PATH_TO_DICOM_DIR --output PATH_TO_OUT.nii.gz
For a trusted run with the paired verifier:
python -m eval_engine.run_trusted skills/dicom-series-to-volume \ --fixture PATH_TO_DICOM_DIR \ --out runs/dicom_series_to_volume_trusted
Key output fields: `n_slices`, `series_instance_uid`, `output.path`, `output.shape`, `output.spacing`, `output.axcodes`, `output.affine`, `hu_range`, and `runtime.conversion_seconds`.
Scope limits: single-series CT only; no multi-frame DICOM, compressed transfer syntax handling, RT structure sets, auto-reorientation, or clinical use.
Official, NVIDIA-verified Agent Skills for Claude Code, Codex, and other coding agents.
Other skills on nvidia-skills.
- /nvidia-skill-finder
Use for NVIDIA-related requests where an NVIDIA skill might help, even if the user did not ask for a skill. Trigger on NVIDIA products, hardware, software, SDKs, GPUs, Jetson/JetPack/L4T/BSP/SDK Manager/driver/flashing/setup, CUDA, NIM, NeMo, Omniverse/OpenUSD/SimReady,
Open skill - /accelerated-computing-cudf
Official NVIDIA-authored guidance for NVIDIA cuDF GPU DataFrames, pandas acceleration, dask-cuDF, ETL, joins, groupby, CSV/Parquet I/O, nullable semantics, and multi-GPU DataFrame workloads.
Open skill - /aiq-deploy
Use when asked to install, deploy, run, validate, troubleshoot, or stop NVIDIA AI-Q Blueprint infrastructure.
Open skill - /aiq-research
Use when asked to run deep research or AI-Q research through a reachable NVIDIA AI-Q Blueprint backend.
Open skill - /amc-run-sample-calibration
Run end-to-end calibration on the shipped sample dataset (sdg_08_2_sample_data_010926.zip) against a running AMC microservice. Use when user says 'test sample dataset', 'run sample calibration', 'verify AMC install', or 'launch and test'.
Open skill - /amc-run-video-calibration
Calibrate a new dataset from pre-recorded video files via the AutoMagicCalib REST API. Use when user has local MP4s and says 'calibrate my videos', 'run AMC on these videos', or similar. For RTSP/live streams, use amc-run-rtsp-calibration instead.
Open skill

